§ 18-62. Fire rating, exterior wall adjacent to residential buildings.  


Latest version.
  • (a)

    The exterior walls of each building that is adjacent to a structure containing any residential living unit(s) shall have minimum fire ratings as follows:

    (1)

    Walls having less than ten feet separation from adjacent residential building:

    > 1-hr. fire rating (minimum); no openings.

    (2)

    Walls having ten—15 feet separation from adjacent residential building:

    > 1-hr. fire rating (minimum); openings not to exceed ten percent of wall space.

    (3)

    Walls of buildings fully protected by 13R sprinkler system (Ark. Fire Prot. Code):

    > exempt; provided that walls having less than three feet separation from adjacent residential building shall comply with AFPC § R302.

    (b)

    Any existing or previously-permitted building that is not in compliance with this section shall be deemed a legal non-conforming structure, and shall be subject to the terms of Chapter 102, Article VI ("Nonconforming uses") of this Code.